Analysis of common failures of can Baler 1. The machine is not working, but the pump is still running
2. The direction of rotation of the motor is reversed. Check the direction of rotation of the motor;
3. The voltage of the motor is too low to operate normally under the existing load, check the voltage;
4. Check if there is any hose leakage or being pinched in the hydraulic pipeline;
5. Check whether the hydraulic oil in the oil tank is sufficient (the liquid level should be above 1/2 of the tank volume);
6. The suction filter of the fuel tank or the vent cap on the top may be clogged;
7. Check whether the suction pipeline device is loose, whether there are capillary cracks in the suction port of the pump, the suction pipeline should always have oil and no bubbles;

The above are the common faults of the can Baler organized by Nick Machinery for everyone. Is it helpful to you? If you encounter other problems during use, please contact our staff at 86-29-86031588, and we will serve you wholeheartedly